MOLDPRO

Introduction | Technical Specification | Technical Data | Literature

MOLDPRO Technical Data

General data:
- Suitable for clean room classification:
class 10.000
classification:
(US Fed. Standard 209 D)
(class 1.000)
- Installation dimension: L 2.93 x W 0.94 x H 1.79 m
- Required floor space: 2.75 m2
- Net weight: approx. 2.5 t
- Floor load
(static load, vertical direction):
~ 1.000 kg/m2
- Dynamic force: 1 kN
- Atmosphere: no corrosive gases allowed
Mold temperature controller:
- Model: SINGULUS
- Type: TCU 1
- Max. temperature: 140 °C
- Cooling methode: indirect by cooling liquid
Injection unit:
- Adjustable barrel heating zones: 6 incl. Nozzle heating
- Total heater capacity: 9.4 kW
Motor rated power:
- Clamping unit: 54 kW (3 x 18 kW)
- Injection unit: 11 kW
Media consumption:
- Water: < 25 l/min
- Compressed air: < 150 l/min (cycle time 2.2 s)
- Electricity: During production < 10 kW
- Heat loss to the environment:
· Cooling water: ~ 5 kW
· Atmosphere: ~ 5 kW
Cycle times:
- CD-Audio/ROM: 3.2 s
- DVD-5/9/10: 2.3 s
- HD DVD: 3.5 s
- BD: 4.0 s
Electrical power:
- Voltage: 3 x 400 V, PE, +/- 5%- Type TCU 1
- Frequency: 50 Hz / 60 Hz
- Total connected power: < 35 kW
- Total connected power: < 10 kW
- Main circuit breaker: 63 A CE
- Connection: L1, L2, L3, PE